How many compartments, partitions and doors does your aviary need? Enter the number of hens, the usable length of the house and the number of rows. The calculator tries dividing with vertical partitions, with horizontal walls or with both at once, draws the plan and tells you how many compartments and inspection doors you get.

Aviary compartments
Time to plan! Enter your figures and we will split the house into compartments.12 compartments3 walls parallel to the rows, in groups of 2 rows8 transverse partitions inside the groups, one every 18 mAbout 16 inspection doorsAt most 3,417 hens in each compartment
It is a representation to set out the problem: your engineer or adviser works out the final layout.
Aviary row Partition, wall or end wall Inspection door
Measured twice: all the sections come out equal.- Under RSPCA (United Kingdom), welfare standards for laying hens, 1 July 2025 (RSPCA Assured private standard), E 7.6: In flocks of more than 6,000 hens, at most 4,000 per compartment, with partitions that stop birds moving between them. A British private standard, not law. With smaller compartments, a fright or a smothering incident affects fewer hens.
How it is counted
Vertical: wall-to-wall partitions that cross all the rows. Horizontal: walls parallel to the rows, in the aisle between two groups of rows; each group is a compartment. Mixed: walls between groups of rows and, inside each group, transverse partitions.
The compartments are also closed at both ends. Doors: one for each aisle that a partition or an end wall crosses (at least one per group, even a single row). Parallel walls have no door: you get from one group to the next through the ends. It is an approximate, example count: it does not include the side aisles or the way through for the belts.
Each parallel wall is assumed to stand in the aisle between two rows, with each compartment keeping its half of the aisle. The rows are split into groups as equal as possible: the calculator tries every grouping and shows the one with the fewest doors for each type.
Try this layout in the simulator →
An indicative result, for information purposes and under the chosen rules. It does not replace the technical design, the vet or the official inspection: have it checked by your equipment supplier or your adviser. Rules change and each country may be stricter: always check the text in force.
Explained in the simulator manual
Designing the whole aviary? Try the simulator →
What the limits are
- In organic, Regulation (EU) 2018/848 does not allow more than 3,000 laying hens in a single compartment.
- In conventional, Directive 1999/74/EC sets no maximum per compartment.
- The RSPCA (United Kingdom; a private standard, not law) recommends at most 4,000 per compartment in flocks of more than 6,000 hens, with partitions that stop birds moving from one to another.
Every figure, with its article, is in EU rules for laying hen aviaries.
Vertical, horizontal or mixed
- Vertical: transverse partitions, wall to wall, that cross all the rows and their aisles. If they cross the aisles, they need doors or inspection gaps: one for each aisle and each partition.
- Horizontal: walls parallel to the rows, in the aisle between two groups of rows. Each group is a compartment, so they only work if a single row, or a group of rows, already meets the limit.
- Mixed: walls between groups of rows and, inside each group, transverse partitions. Because each partition crosses fewer aisles, it usually needs far fewer doors.
In all of them, the compartments are also closed at both ends. The calculator tries every way of grouping the rows and shows, for each type, the one that needs the fewest doors. It counts one door for each aisle that a partition or an end wall crosses, at least one per group; parallel walls have no door, because you get from one group to the next through the ends. It is an approximate, example count.
It does not count nest dividers, which split the laying spaces to control how many hens crowd together and do not necessarily cut the aisles or the whole height of the aviary: they do not separate flocks. In a study of Italian aviaries (Nannoni and others, 2022), for example, the partitions inside each tier formed cells of 3.6 × 1.1 m, each with its nest, drinkers and feeder.
An example
With 41,000 hens, 54 m usable and 8 rows, with the RSPCA recommendation:
- Vertical: 11 compartments, a partition every 4.9 m and about 84 doors.
- Horizontal: not enough, because a single row already has 5,125 hens, more than 4,000.
- Mixed: 4 groups of 2 rows, with 3 sections each: 12 compartments and about 16 doors.
In organic, with the 3,000 limit, vertical gives 14 compartments and about 105 doors, and mixed, with 4 groups of 2 rows and 4 sections, 16 compartments and about 20 doors.
Frequently asked questions
How many hens can there be in a compartment?
In organic, 3,000 at most. In conventional, the European directive sets no maximum. The RSPCA recommends 4,000 in flocks of more than 6,000 hens; with 6,000 or fewer it does not ask for any division.
Why do the doors change so much from one type to another?
Because each vertical partition crosses all the aisles between rows and every aisle needs a door. If the rows are first grouped with horizontal walls, each partition only crosses the aisles of its own group, and far fewer doors are left.
How do I see it drawn?
The calculator draws the plan of the chosen type: rows in green, partitions and walls in dashed grey, the end walls in black and doors in orange. The “Try this layout in the simulator” button opens the simulator with your house and the chosen type, with its partitions, walls and doors drawn; and from the simulator, “Work out the compartment layout” brings you back here with your design.
And the rest of the aviary?
Also see how many hens fit per square metre, or try the aviary simulator, which checks everything at once; each value is explained in its manual.